HOME > Business area > Construct/Maintain water quality TMS and water quality analyzer > TMS Analyzer for water quality, Analyzer for water

  • A legal basis
    Rules from section 2(attachment of measuring instrument and etc) to section 5 Of Article 38 of the law on Water quality and aquatic ecosystems preservation.
  • purpose
    As a business for constructing the water quality TMS with an automatic water quality measuring system for managing and checking through online monitoring water quality pollution level of the sewage/wastewater treatment facility or the workplace discharging wastewater, it manages and checks in real time the design, production, installation, test run, technical support and draining quality to prevent its water quality pollution event and to analyze and manage the current condition of water quality and induces autonomously improvement and recognizes exactly the pollution level of the discharge to come true the water quality control on advanced and scientific basis such as the rational and objective imposition of effluent charge and etc

Water quality TMS Analyzer measurement method measurement range specification
1.BOD Analyzer Microbial fuel cell using electrochemically active bacteria 0.1~200mg/L (allow to set its range) 600(W) X 662(D) X 1,700(H)mm
2.COD Analyzer Acidic/alkaline KMnO4 method. 0~200mg/L (allow to set its range) 570(W) X 630(D) X 1,440(H)mm
Electrochemical decomposition 0~200mg/L (allow to set its range) 600(W) X 662(D) X 1,700(H)mm
3.T-N Analyzer UV spectrometric method 0~5/20/50/100mg/L (allow to set its range) 600(W) X 410(D) X 1,680(H)mm
4.T-P Analyzer Molybden blue spectrometric method 0~10mg/L (allow to set its range) 600(W) X 354(D) X 1,100(H)mm
5.pH Meter Complex glass electrode method 0~14(pH)  
6.SS Meter Measure the scattered light at 880nm. Within 0~100mg/LÀ̳»(SS)  

 

Water quality Analyzer measurement method measurement range specification
1.TOC Analyzer Dual Oxidation NDR Method 0~25/50/100/10,000mg/L (allow to set its range) 508(W) X 381(D) X 508(H)mm
2.PO©þ-P Analyzer spectrometric molybdenum method 0~0.1/2/5/10mg/L (allow to set its range) 600(W) X 354(D) X 1,100(H)mm
3.NO©ý-N Analyzer Direct determination 0~20mg/L (allow to set its range) 600(W) X 354(D) X 1,100(H)mm
4.NH©ý-N Analyzer Salicylate method induced by indophenol method 0~16mg/L (allow to set its range) 600(W) X 354(D) X 1,100(H)mm